Home
International Journal of Science and Research Archive
International, Peer reviewed, Open access Journal ISSN Approved Journal No. 2582-8185

Main navigation

  • Home
    • Journal Information
    • Abstracting and Indexing
    • Editorial Board Members
    • Reviewer Panel
    • Journal Policies
    • IJSRA CrossMark Policy
    • Publication Ethics
    • Issue in Progress
    • Current Issue
    • Past Issues
    • Instructions for Authors
    • Article processing fee
    • Track Manuscript Status
    • Get Publication Certificate
    • Become a Reviewer panel member
    • Join as Editorial Board Member
  • Contact us
  • Downloads

ISSN Approved Journal || eISSN: 2582-8185 || CODEN: IJSRO2 || Impact Factor 8.2 || Google Scholar and CrossRef Indexed

Peer Reviewed and Referred Journal || Free Certificate of Publication

Research and review articles are invited for publication in October 2026 (Volume 21, Issue 1) Submit manuscript

OPERATIONAL IMPACT ASSESSMENT OF ROOFTOP SOLAR PV AND BATTERY ENERGY STORAGE INTEGRATION ON A 22 KV URBAN DISTRIBUTION FEEDER IN DA NANG CITY, VIETNAM

Breadcrumb

  • Home
  • OPERATIONAL IMPACT ASSESSMENT OF ROOFTOP SOLAR PV AND BATTERY ENERGY STORAGE INTEGRATION ON A 22 KV URBAN DISTRIBUTION FEEDER IN DA NANG CITY, VIETNAM

Nguyen Ba Giap * and Tran Dinh Dung

College of Engineering and Technology – Vinh University – 182 Le Duan – Truong Vinh Ward – Nghe An – Vietnam.
* Corresponding Author

Research Article

International Journal of Science and Research Archive, 2026, 21(01), 345–359

Article DOI: 10.30574/ijsra.2026.21.1.1903

DOI url: https://doi.org/10.30574/ijsra.2026.21.1.1903

Received on 05 September 2026; revised on 12 October 2026; accepted on 14 October 2026

The rapid growth of rooftop solar photovoltaic (PV) systems is turning urban distribution feeders from passive, unidirectional circuits into active networks with variable and bidirectional power flows. This paper assesses the operational impact of rooftop PV and battery energy storage systems (BESS) on a real 22 kV urban feeder (outgoing feeder 480 of the 110 kV ADO substation) in Da Nang City, Vietnam. A network model with 17 medium-voltage nodes and 49 monitored 0.4 kV busbars was built in DIgSILENT PowerFactory from utility network data and measured PV and load profiles. Newton–Raphson load-flow studies (11:00, 20:00 and 24-hour profiles) and RMS simulations of cloud-cover and thunderstorm events, with PV represented as constant-power static generators, were carried out for the existing network, for a doubled-PV scenario with distributed BESS and for a load-levelling BESS. With 1.9 MWp of existing rooftop PV (about 16% of the feeder peak) all voltages stay within ±5% of nominal (maximum 1.045 p.u. at the substation bus, 1.026 p.u. at 0.4 kV). The simulated events cause voltage steps of about 0.001 p.u. and short spikes in the local bus-frequency signal (minimum 49.816 Hz; 49.805 Hz with PV doubled); because inverter controls and upstream-grid dynamics are not modelled, this signal is used only as a relative screening indicator and not as a system-frequency result. Doubling the PV capacity to 3.8 MWp with distributed BESS reduces the noon active-power loss by 28% and the daily energy loss by 11.5%. A partial-deployment load-levelling dispatch of 0.62 MW (about 11% of the 5.6 MW / 11.7 MWh design) lowers the evening peak by 5.1%, raises the night valley by 8.1% and cuts active and reactive losses at 20:00 by 21% and 19%; the full design is assessed only economically. A 20-year cash-flow model of the 11.7 MWh BESS gives NPV ≈ VND 113 billion, IRR ≈ 21.8% and a discounted payback of about 6 years under the assumed tariffs, but NPV falls to VND 28 billion if the peak price is 40% lower and to VND 56 billion without tariff escalation, and it is close to zero under combined adverse assumptions, so the economic result is preliminary. The results provide quantitative guidance for utilities planning PV hosting and storage deployment on urban 22 kV feeders.

Rooftop Solar PV; Battery Energy Storage System (BESS); Distribution Network; Load Flow; Voltage Profile; Power Loss; Peak Shaving; Digsilent Powerfactory

https://ijsra.net/sites/default/files/fulltext_pdf/IJSRA-2026-1903.pdf

Preview Article PDF

Nguyen Ba Giap and Tran Dinh Dung. OPERATIONAL IMPACT ASSESSMENT OF ROOFTOP SOLAR PV AND BATTERY ENERGY STORAGE INTEGRATION ON A 22 KV URBAN DISTRIBUTION FEEDER IN DA NANG CITY, VIETNAM. International Journal of Science and Research Archive, 2026, 21(01), 345–359. Article DOI: https://doi.org/10.30574/ijsra.2026.21.1.1903.

Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


All statements, opinions, and data contained in this publication are solely those of the individual author(s) and contributor(s). The journal, editors, reviewers, and publisher disclaim any responsibility or liability for the content, including accuracy, completeness, or any consequences arising from its use.

Get Certificates

Get Publication Certificate

Download LoA

Check Corssref DOI details

Issue details

Issue Cover Page

Editorial Board

Table of content

          

   

Copyright © 2026 International Journal of Science and Research Archive - All rights reserved

Developed & Designed by VS Infosolution